1.
Diabetes Technol Ther ; 25(12): 893-901, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37956265

RESUMEN

Background: Evaluate the impact of the MiniMed™ 780G advanced hybrid closed-loop (AHCL) system on the glucose profile of pregnant women with type 1 diabetes (T1D) and maternal-neonatal complications. Methods: From April 2021 to September 2022, pregnant women with T1D treated with the AHCL system were included in an observational multicenter retrospective study. Continuous glucose monitoring parameters were analyzed monthly during pregnancy as well as maternal-neonatal complications. Results: Thirteen pregnant women, including a twin pregnancy (age: 33 ± 3 years, hemoglobin A1c [HbA1c]: 7.3% ± 0.7%, insulin doses: 0.72 ± 0.21 U/kg/day) were analyzed. At delivery, gestational age was 37 ± 2 weeks. During first 2 weeks of pregnancy, time in range (TIR, 63-140 mg/dL) was 46% (34-55) and increased to 54% (51-59) (P < 0.01), 64% (48-68) (P < 0.01), and 66% (60-70) (P < 0.001) during the first, second, and third trimester, respectively. During the night, TIR (63-140 mg/dL) was >70% throughout pregnancy. Time below the range <63 mg/dL increased from 0.5% (0-2) to 1.3% (0.7-2.2), 2% (1.2-3.5) (P < 0.05), and 1.3% (1.31-3) (P < 0.05) during the first, second, and third trimester, respectively. At delivery, insulin doses increased to 0.89 ± 0.35 IU/kg/day (P < 0.01), and HbA1c decreased to 6.4% ± 0.6% (P = 0.005). The reported carbohydrate amount increased from 167 ± 363 g/d during early pregnancy to 243 ± 106 g/d (P < 0.01) at delivery. The birthweight was 3134 ± 711 g, with 5/14 macrosomia and 2/14 neonatal hypoglycemia. Moreover, 5/13 patients had a preeclampsia and 9/13 a cesarean section, including three cases of scarred uterus. The Clinical Trial Registration number is: CE-2022-55. Conclusion: The AHCL system provided good glucose control during pregnancy and recommendation targets were reached during the nocturnal period only. The maternal and neonatal complications remained high.


Asunto(s)
Diabetes Mellitus Tipo 1 , Embarazo en Diabéticas , Adulto , Femenino , Humanos , Recién Nacido , Embarazo , Glucemia , Automonitorización de la Glucosa Sanguínea , Cesárea , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Glucosa , Hemoglobina Glucada , Hipoglucemiantes/administración & dosificación , Insulina/administración & dosificación , Sistemas de Infusión de Insulina/efectos adversos , Embarazo en Diabéticas/tratamiento farmacológico , Mujeres Embarazadas , Estudios Retrospectivos
2.
Prim Care Diabetes ; 13(1): 63-70, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30268507

RESUMEN

AIMS: To understand the opinions of children with type 1 diabetes about their everyday use of flash glucose monitoring. (FGM). METHODS: Children with type 1 diabetes using the FreeStyle Libre® FGM system and/or their parents were surveyed in several French medical centers between December 2016 and June 2017, regardless of their treatment regimen and metabolic control. RESULTS: Of the 347 patients recruited, 79.5% had been using the sensor for more than three months (average usage time: 285 days). The main reported motivations for initiating this type of monitoring were to avoid finger prick pain (for 85.9% of patients) and to allow parents to check nocturnal glucose levels (60.8%). Two-thirds of respondents experienced difficulties, mainly the sensor falling off (47.6%), measurement discrepancies (25.1%) and cutaneous reactions (22.2%); 89.5% changed their habits: 70.6% took more scans, 37.2% corrected their hyperglycemia more promptly, and 37.5% used trends to adjust their insulin dosage. About one-third of the study group (35.1%) experienced lower HbA1c levels, and two thirds (67.1%) were satisfied with the device. CONCLUSIONS: Our results show that FGM is a widely accepted option for self-monitoring diabetes, but that specific training is required to improve its use for insulin dosage adjustment and metabolic results.


Asunto(s)
Automonitorización de la Glucosa Sanguínea/instrumentación , Glucemia/metabolismo , Diabetes Mellitus Tipo 1/diagnóstico , Satisfacción del Paciente , Adolescente , Conducta del Adolescente , Factores de Edad , Biomarcadores/sangre , Niño , Conducta Infantil , Preescolar , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/psicología , Diseño de Equipo , Femenino , Francia , Hemoglobina Glucada , Hábitos , Encuestas de Atención de la Salud , Conocimientos, Actitudes y Práctica en Salud , Humanos , Hipoglucemiantes/administración & dosificación , Lactante , Recién Nacido , Insulina/administración & dosificación , Masculino , Motivación , Padres/psicología , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Estudios Retrospectivos , Factores de Tiempo